Safety Precautions
Electrical equipment should be installed, operated, serviced and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material.
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices. See NFPA 70, CSA Z462, or NOM 029-STPS.
This equipment must only be installed and serviced by qualified electrical personnel.
Turn off all power supplying this equipment before working on or inside equipment.
Always use a properly rated voltage sensing device to confirm power is off.
Replace all devices, doors, and covers before turning on power to this equipment.
Beware of potential hazards, and carefully inspect the work area for tools and objects that may have been left inside the equipment.
Failure to follow these instructions will result in death or serious injury.
The Wiser Energy System has been tested and certified for use with Square D™ circuit breakers, load centers and combination service entrance devices (CSEDs) as installed per this manual.
For use in non-Square D load centers and CSEDs please consult with the manufacturer for compatibility.
Specifications
Technical Specifications
Wiser Energy is a home energy monitoring device. It is used to measure the current and voltage on the service mains. The device monitors two phases of 120 VAC. If installed outside, it must be kept dry and within specified temperature ranges.
Current Sensor Specifications
CAT IV 250 V 200 A max
Cable length: 46 in. | Inside diameter: 0.95 in.
May be used on uninsulated conductors
Monitor Specifications
Compatibility: 120 VAC (90 V–130 V)
Power Use: < 5 Watts, 0.1 amps
Wi-Fi: 2.4 GHz 802.11b/g/n
Size: 137 mm x 66 mm x 32 mm
Weight: 200 g
Climate Specifications
RH <90%; IPx0 rating
Temperature: 32 – 154.4 ºF (0 – 68 ºC)
Elevation < 6,561 ft. (<2,000 m)
Legal
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. Operation is subject to these conditions:
1. It may not cause harmful interference.
2. It must accept any interference received, including interference that may cause undesired operation. If it is not installed and used as per the instructions, it may cause interference which is harmful to wireless communications. There is no guarantee that interference will not occur in a particular installation. If it does cause interference we recommend: reorienting or relocating the receiving antenna, or increasing the separation between the device and the receiver.
3. Patents: sense.com/patents
Certified to CSA STD C22.2 No. 61010-1
Conforms to UL STD 2808
Conforms to UL STD 61010-1
Conforms to UL STD 61010-2-032
Conforms to CAN ICES-3(B)/NMB-3(B)